Synthes va prox tibia inventory. The A.L.P.S Distal Tibia Plating System represents th...

The proximal portion of the plate is anatomically contoure

6 Surgical Technique • LCP Anterolateral Distal Tibia Plate 3.5 Position patient Position the patient supine on a radiolucent operating table. Visualization of the distal tibia under fluoroscopy in both the lateral and AP views is recommended. Elevate the leg on a padded rest with the knee moderately flexed to placement in a neutral position.General Remarks Open-wedge corrective tibia osteotomies are increasingly being used for joint-preserving surgery of the knee joint. The TomoFix knee osteotomy system is based on the Locking Compression Plate system (LCP) and enables angular-stable connections between the screw and plate. This angular stability allows the stable fixation of an open …Inventory; Delete Set. Manage Set Trays and Contents Save Changes. UNIVERSAL SMALL FRAGMENT VA-LCP PROX TIBIA SET EVAL Add Tray Kit Trays and Contents Collapse All Expand All. Primary Tray (34 Parts) Add products to tray Move To; Top of the kit; Bottom of the kit ...Our 3.5mm LCP™ Olecranon Plates are part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. Available in stainless steel or titanium, these plates are designed to address fractures, osteotomies, and non-unions of the olecranon. Product Specifications.The DePuy Synthes VA-LCP PPFx Proximal Femur Plating System 3.5/4.5/5.0 is con - traindicated for independent fixation if the hip stem requires immediate revision. The DePuy Synthes VA-LCP PPFx Proximal Femur Hook Plate 3.5/4.5/5.0 with 5 holes (shortest plate) is contraindicated for diaphyseal periprosthetic femoralThe Universal Small Fragment (USF) System is intended to be used for small bone trauma, including anatomy such as Shoulder, Clavicle, Elbow, Tibia and Fibula. The core set can support any DePuy Synthes 2.7mm or 3.5mm non-locking, LCP® or VA LCP® Implant System. Training topics for USF. System Trays. Instruments.The distal tibia plates are made of stainless steel and are an extension of the ankle fracture management system. Plates have been designed with concern for the thin soft tissues on the tibia and are low profile with 2.7 mm locking or non-locking screws in the distal portion of each plate. Medial, anterolateral, anterior, posterior and small rim plates complete the plating offering for the ...2 Synthes LCP Proximal Tibial Plate 3.5 Technique Guide The LCP Proximal Tibial Plate 3.5 is part of the Small Frag-ment LCP System, which merges locking screw technology with conventional plating techniques. The LCP Proximal Tibial Plate 3.5 has a limited-contact profile. The head and neck portions of the plate accept 3.5 mmLCP™ Proximal Femur Plate (4.5/5.0mm) Variable Angle LCP™ Ankle Trauma System (2.7 mm/3.5 mm) 3.5 mm LCP ® Anterolateral Distal Tibia Plates; 3.5 mm Variable Angle LCP ® Proximal Tibia Plate; 4.5 mm LCP ® Proximal Tibia Plate; Continuous Compression Implants for Trauma Applications; TomoFix ® Medial High Tibia Plate; Power Tools. UNIUM ...INVENTORY CONTROL FORM. Universal Small Fragment System. 3.5 mm VA LCP® Proximal Tibia Implant Set 01.133.213. Case ID: To Order (USA): (800) 523-0322 To …In this educational video, the procedure for the fixation of a tibial plateau bicondylar fracture, type 41C3, will be demonstrated using the 3.5 VA LCP Proxi...AA Medical Store improves healthcare around the world by supplying refurbished state-of the-art surgical devices at the best price, with the best warranty, and unmatched service and support.LCP Medial Proximal Tibial Plate 3.5 LCP Medial Proximal Tibial Plate 4.5/5.0 LCP Metaphyseal Plate for distal medial tibia LCP Metaphyseal Plates LCP Olecranon Plate LCP Pediatric Condylar Plate 90°, 3.5 and 5.0 LCP Pediatric Plate System LCP Periarticular Proximal Humerus Plate 3.5 LCP Posterior Medial Proximal Tibial Plate 3.52 Surgical Technique • VA LCP™ Ankle Trauma System 2.7/3.5 • 2.7 mm variable angle locking screws • Distribution of screws across the pilon (as shown in figure 1) • Plates with rounded edges • Anatomically contoured • Low screwhead prominence Cross-sections of the VA LCP Anterolateral Distal Tibial Plate 2.7/3.5 (1) andOur LCP™ Hook Plate is part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The stainless-steel plate features pointed hooks to aid in plate placement and holes for both lag screws and locking screws. Product Specifications. How to Use This Product.Apply the insertion handle to the medial side of the tibia for nail insertion and proximal locking. Tighten the whole assembly with the 11.0 mm Combination Wrench (321.160). Check that the assembly is stable but not overtightened. Screw the In-serter/Extractor for UTN/CTN (D) (356.490) onto the connect -ing screw.LCP™ Proximal Femur Plate (4.5/5.0mm) Variable Angle LCP™ Ankle Trauma System (2.7 mm/3.5 mm) 3.5 mm LCP ® Anterolateral Distal Tibia Plates; 3.5 mm Variable Angle LCP ® Proximal Tibia Plate; 4.5 mm LCP ® Proximal Tibia Plate; Continuous Compression Implants for Trauma Applications; TomoFix ® Medial High Tibia Plate; Power Tools. UNIUM ...Synthes VA Ankle Trauma is used for ankle fixation in adults and children (12-21) whose growth plates have united, especially in osteopenic bone. The plates are a component of the DePuy Synthes Variable Angle Locking Compression (VA LCP) System, which combines traditional plating methods with technology for variable angle locking screws. The plates are in stainless steel and have an ...The Universal Small Fragment (USF) System is intended to be used for small bone trauma, including anatomy such as Shoulder, Clavicle, Elbow, Tibia and Fibula. The core set can support any DePuy Synthes 2.7mm or 3.5mm non-locking, LCP® or VA LCP® Implant System. Training topics for USF. System Trays. Instruments.The 3.5 mm LCP Proximal Tibia Plates have a limited-contact profile. The head and neck portions of the plates accept 3.5 mm StarDrive™ Recess Locking Screws. The screw hole pattern allows a raft of subchondral locking screws to buttress and maintain reduction of the articular surface. This provides resistance to local depression loads in ...The Synthes LCP Proximal Femoral Plate 4.5/5.0 is part of the LCP Periarticular Plating System, which merges locking screw ... - complex fractures of the proximal tibia with the LCP Proxi-mal Tibia Plate 4.5/5.0 or the Medial Proximal Tibia Plate 4.5/5.0. Locking Compression Plate The Locking Compression Plate (LCP) has combi-holes in the ...Surgical Technique VA-LCP Proximal Tibial Plate 3.5 DePuy Synthes 9 Plate Insertion and Fixation 1. Determine plate type Instruments 03.127.012 Trial Implant for VA-LCP Proximal Tibial Plate 3.5, Small Bend, right, with 6 marked holes 03.127.013 Trial Implant for VA-LCP Proximal Tibial Plate 3.5, Small Bend, left, with 6 marked holes02.130.150, 02.130.150S, 02.130.151... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle Locking Hand System consists of 40 different basic and specialty plates, available in stainless steel and titanium, including fragment-specific plates designed for lateral and dorsal application in fracture repair and deformity correction.Inventory Control Form Variable Angle Locking Hand System Titanium 1.3 mm Titanium Locking Plates* 04.130.150 Straight Plate, 6 holes 04.130.151 Straight Plate, 12 holes 04.130.152 T-Plate, 3 holes head, 5 holes shaft 04.130.153 Y-Plate, 3 holes head, 5 holes shaft 04.130.154 Phalangeal Base Plate, 2 holes head, 5 holes shaftDepuy Synthes GmbH OrthoKit® Rental Service Im Brunnenfeld 8 D-79224 Umkirch www.depuysynthes.com L182.390S B01T01 ***End of document*** LCP Proximale Tibiaplatte 4.5/5.0, lateral, steril Number: TV-SPEC-53116 Version: 1.0 Status: Effective Material Code: Effective Date: 31 Jul 2020 (EST)About This Product. Synthes Calcaneal Plate family including VA Locking Calcaneal Plates 2.7 and Variable Angle Locking Anterolateral Calcaneal Plate 2.7 is intended for temporary fixation, correction, or stabilization of the Calcaneus. Get in Touch with a Sales Consultant.The DePuy Synthes 4.5 mm Variable Angle (VA) LCP® Curved Condylar Plate is part of the VA LCP Periarticular Plating System which merges variable angle locking screw technology with conventional plating techniques. The 4.5 mm VA LCP Curved Condylar Plate System has many similarities to standard locking fi xation methods, with a few8ePuy D Synthes 2.4 mm/2.7 mm Variable Angle LCP® Forefoot/Midfoot System Surgical Technique PROXIMAL AND DISTAL REAMERS Proximal Reamers • Concave shape to form a sphere on the joint surface • Leading-edge radius to help prevent soft-tissue damage Distal Reamers • Convex shape to form a pocket in the joint surfaceSynthes 3.5 mm VA-LCP PROX TIBIA PLATE SMALL BEND/6H/117 mm/LEFT Condition: Used 02.127.221 ... Inventory. Warranty. All For warranty information please visit our FAQ page. Related Products 532.022 Synthes K-Wire Coupling. $50.00 ...Inventory Control Form 2.7 mm/3.5 mm Distal Fibula Plate System Titanium 406.026 Length 404.810 10 mm 404.812 12 mm 404.814 14 mm 404.816 16 mm 404.818 18 mm 404.820 20 mm 404.822 22 mm 404.824 24 mm 404.826 26 mm 404.828 28 mm 3.5 mm Titanium Locking Screws, self-tapping, with StarDrive Recess 412.101 10 mm 12 mm 412.103 14 mm 16 mm 412.105 18 mmLCP Periarticular Proximal Humerus Plate 3.5 LCP Posterior Medial Proximal Tibial Plate 3.5 LCP Proximal Femoral Hook Plate 4.5/5.0 LCP Proximal Femoral Plate 4.5/5.0 LCP Proximal Radius Plates 2.4 LCP Proximal Tibial Plate 3.5 LCP Proximal Tibial Plate 4.5/5.0 with Periarticular Aiming Arm Instruments LCP Superior Anterior Clavicle Plate LCP ...Inventory Control Form 2.7 mm/3.5 mm LCP Distal Fibula Plate System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. DISTFIBICF001 05/22 2 Length 206.028 28 mm 206.030 30 mm 206.035206.014 35 mmDCPTM and LC-DCPTM Systems - synthes.vo.llnwd.netThe Synthes 3.5 mm VA-LCP® Proximal Tibia Plate is part of the VA-LCP Periarticular Plating System which merges variable angle locking screw technology with conventional plating techniques. The 3.5 mm VA-LCP Proximal Tibia Plate System has many similarities to standard locking fixation methods, with a few important improvements.DePuy Synthes 2.7mm VA LCP Clavicle Plates Surgical Technique Guide, 103752541 rev 2 01/21. 2. DePuy Synthes. Shape Verification Analyses. Windchill #0000290902, 0000295170, 0000290186, 0000290903 ...DESCRIPTION. The LCP™ Locking Attachment Plate offers an alternative to cerclage cables and uses a connecting screw to augment the stabilization of fractures. The locking capability stabilizes fixed-angle constructs in periprosthetic fractures, and fractures in the presence of intramedullary implants. Product Specifications.Synthes 3.5 mm VA-LCP PROX TIBIA PLATE SMALL BEND/6H/117 mm/LEFT Condition: Used 02.127.221 ... Inventory. Warranty. All For warranty information please visit our FAQ page. Related Products 532.022 Synthes K-Wire Coupling. $50.00 ...3.5 mm. Remove the cortex screw from hole 1 and replace it with a bicortical, self-tapping locking screw. Screw the drill sleeve exactly into the threaded part of the combi-hole and drill the hole with the LCP drill bit 4.3 mm. Determine the screw length and insert the screw as described on page 15.Complete the preoperative radiographic assessment and prepare the preoperative plan. Determine plate length and Position the patient supine on a radiolucent operating table. 3.5 mm LCP Low Bend Medial Distal Tibia Plates set 01.1 12.062 Tray for LCP Medial Distal Tibial Plate 3.5, low bend (TAN), for Vario Case, without Lid, with Contents 01.1 12.063 Tray for LCP Medial Distal Tibial Plate 3.5 ...Part of the complete Synthes LCP Elbow Set LCP Olecranon Plate Variety of plates: - Left and right version - Choice of six lengths with 2, 4, 6, 8, 10 or 12 LCP combi-holes in the shaft Proximal portion of the plate with 8 locking holes allows to set a maximum number of locking screws. Guide block for easy and correct insertion Indications ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Instruments Patient Information: J9794-B 5/11 Inventory Control Form 3.5 mm LCP Periarticular Proximal Humerus Plates 3.5 mm LCP Periarticular Proximal Humerus Plates HOLES 02.123.020 2, right 02.123.021 2, left 02. ...TFNA - Proximal Femoral Nailing System The Universal Nail System Titanium/Stainless Steel Elastic Nail System UFN Unreamed Femoral Nail CFN Cannulated Femoral Nail UHN/PHN Humeral Nailing System UTN/CTN Solid/Cannulated Tibial Nail Please read these instructions for use, the Synthes brochure "Important Informa-tion" carefully before use.3.5 mm VA LCP® Proximal Tibia Plate System Surgical Technique DePuy Synthes 9 PLATE INSERTION AND FIXATION 1 Determine plate type Instruments 03.127.012 3.5 mm VA-LCP Proximal Tibia Trial Implant, Small Bend, Right 03.127.013 3.5 mm VA-LCP Proximal Tibia Trial Implant, Small Bend, Left 03.127.014 3.5 mm VA-LCP Proximal …The Universal Small Fragment System can support all 2.7 mm/3.5mm non-locking, LCP™ System, and VA LCP™ Locking Technologies. It consists of two components: A core set of instruments, screws, and standard implants. Modular anatomic implant trays for supported small fragment anatomy. Get in Touch with a Sales Consultant.Inventory Control Form 2.7 mm/3.5 mm Distal Fibula Plate System Titanium 406.026 Length 404.810 10 mm 404.812 12 mm 404.814 14 mm 404.816 16 mm 404.818 18 mm 404.820 20 mm 404.822 22 mm 404.824 24 mm 404.826 26 mm 404.828 28 mm 3.5 mm Titanium Locking Screws, self-tapping, with StarDrive Recess 412.101 10 mm 12 mm 412.103 14 mm 16 mm 412.105 18 mmLa plaque LCP de 3.5 mm pour tibia distal médial Low Bend est un composant du système LCP pour petits fragments Synthes qui combine la technologie des vis de verrouillage avec les techniques conventionnelles pour plaque. Les trous combinés de la plaque LCP associent un trou de compression dynamique à un trou de verrouillage.The aim of this study was to evaluate the clinical and/or radiologic outcome using different polyaxial locking plates for the treatment of proximal tibia fractures, the Non-Contact-Briding plate (NCB-PT®) by Zimmer or the Variable Angle Locking Compression Plate (VA-LCP®) by Synthes. This study enrolled 28 patients with proximal tibia …TN-ADVANCED™ Tibial Nailing System | DePuy Synthes. The TN-A is offered inside the following nail diameters: 8.2 mm, 9 mm, 10 width, 11 mm, 12 mm and 13 mm. The proximal napping diameter is 11 mm for all nails with nail shaft diameters from 8.2 mm into 11 mm. With large nail car the proximal nail diameter is the similar as the nail socket side.The DePuy Synthes VA-LCP PPFx Proximal Femur Plating System 3.5/4.5/5.0 is con - traindicated for independent fixation if the hip stem requires immediate revision. The DePuy Synthes VA-LCP PPFx Proximal Femur Hook Plate 3.5/4.5/5.0 with 5 holes (shortest plate) is contraindicated for diaphyseal periprosthetic femoralsynthes.vo.llnwd.netThe tibia is the main bone of the lower leg, forming what is more commonly known as the shin.. It expands at its proximal and distal ends; articulating at the knee and ankle joints respectively. The tibia is the second largest bone in the body and it is a key weight-bearing structure.. In this article, we shall look at anatomy of the tibia - its bony landmarks, articulations and clinical ...Open your synthes 3 5 va proximal tibia inventory in the editor, which is very easy to use and understand. When you go there, you'll be able to black out and change text, write and erase, add images, draw lines, arrows, and more. You can also add sticky notes and text boxes.The DePuy Synthes VA Locking Attachment Plate 3.5 is offered in Stainless Steel mate - rial in both sterile and non-sterile package configurations. It attaches to DePuy Synthes VA-LCP PPFx Proximal Femur Plate or Proximal Femur Hook Plate 3.5/4.5/5.0, VA-LCP Curved Condylar 4.5/5.0, LCP Curved Condylar 4.5/5.0, Straight and Curved Broad LCPThe Arthrex Proximal Tibia Plating System builds on the Titanium Distal Tibia Plating System with the addition of lateral and posteromedial proximal tibia plating options, plateau-specific instruments, and longer screws. All plates accept 4.0 mm fixed-angle locking, 3.5 mm variable-angle locking, and 3.5 mm cortical screws. A T10 driver can be used for all …INVENTORY CONTROL FORM Tibial Nail Advanced System Implants To order (USA): 800-523-0322 To order (Canada): 844-243-4321 Date: Hospital: Surgeon: Procedure: Tibial Nail Advanced System B 8 mm, Sterile Tibial Nail Advanced System B 11 mm, Sterile Tibial Nail Advanced System B 9 mm, Sterile Tibial Nail Advanced System B 12 mm, SterileUSF VA LCP ® Distal Tibial Implant Set 58 USF LCP® Distal Tibial Implant SetUniversal Small Fragment LCP 59 USF VA LCP ® Distal Fibula Implant Set 60 USF VA LCP ® Distal Fibula with 4.0 mm Cortex Screw Implant Set* 61 USF LCP® Distal Fibula Implant Set 62 Instruments3 Instruments 4 Optional Instruments for 4.0 mm Cortex Screws 13A – Stryker AxSOS 3 Ti Proximal Tibia plate; B – Smith & Nephew PERI-LOC Lateral Proximal Tibia plate; C – DePuy Synthes 3.5mm Variable Angle Locking Compression Plate [VA-LCP] Proximal Tibia plate – fixed trajectory; D – DePuy Synthes 3.5mm VA-LCP Proximal Tibia plate – VA screws aimed toward the PMF; E – Zimmer Biomet A.L.P.S ...Open reduction and internal fixation with plates and screws is considered to be todays gold standard method for treatment of proximal tibial fractures. A broad variety of plates is available for this anatomic area, with special features providing solutions to different clinical problems. The VA-Locking Proximal Tibial Plate 3.5 covers various indications with one (small fragment) implant ...The 2.4 mm Variable Angle LCP™ Two-Column Volar Distal Radius Plate works with the 2.4 mm Variable Angle LCP Distal Radius System to address simple and complex fractures in the radius. Some of its key features include: Three head sizes to accommodate patient anatomy (19.5 mm, 22 mm, 25.5 mm) Variable Angle LCP Plate Holes in the head of the ...The Expert Tibial Nail permits an intra medullary approach for the fixation of proximal, shaft and distal fractures of the tibia. The system consists of a series of cannulated nails, can-nulated end caps, dual core locking screws and standard locking screws. All of the implants are made of titanium alloy (TAN*).DESCRIPTION. The LCP™ Locking Attachment Plate offers an alternative to cerclage cables and uses a connecting screw to augment the stabilization of fractures. The locking capability stabilizes fixed-angle constructs in periprosthetic fractures, and fractures in the presence of intramedullary implants. Product Specifications.LCP Periarticular Proximal Humerus Plate 3.5 LCP Posterior Medial Proximal Tibial Plate 3.5 LCP Proximal Femoral Hook Plate 4.5/5.0 LCP Proximal Femoral Plate 4.5/5.0 LCP Proximal Radius Plates 2.4 LCP Proximal Tibial Plate 3.5 LCP Proximal Tibial Plate 4.5/5.0 with Periarticular Aiming Arm Instruments LCP Superior Anterior Clavicle Plate LCP ...Variable Angle Locking Patella Plating System. Product Codes : 02.137.000S, 02.137.001S, 02.137.002S... View More. PRODUCT CODES. DESCRIPTION. The VA Locking Patella Plates are designed for a diverse range of fractures and are universal for either left or right use. Available in Stainless Steel and Titanium, the plates are pre-contoured and ...Variable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.If taking stock of your insurance coverage – be it for your home, car or life –ranks even lower than doing taxes and getting root… By clicking "TRY IT", I agree to receive n...Variable Angle LCP™ Proximal Tibia Plate (3.5 mm) 02.211.201, 02.211.201S, 02.211.202... Part of the Periarticular Plating System which merges variable angle locking screw technology with conventional plating techniques, this plate provides a fixed-angle construct while allowing surgeons the freedom to choose the screw trajectory before ...SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J5632-H 11/12 Inventory Control Form Titanium Cannulated Tibial Nail-EX Titanium Cannulated Tibial Nail-EX, sterile 8.0 mm diameter LENGTH LENGTH 04.004.231S 255 mm 04.004.234S 270 mm 04.004 ...External Fixator Devices include pins, wires, rods and clamps to form a frame for the reposition and fixation of bone fragments. Pins and wires are single-use im-plants and build the connection of the frame to the bone(s). Rods and clamps are the parts of the frame that are located outside of the body and are designed for multiple usages.2.7mm va-lcp distal tibia t-plate/6 holes-sterile synthes gmbh. fda.report › gudid › synthes gmbh › h67902118307s0. ... 3.5mm va-lcp prox tibia trial implant-small bend/3h/rt: h679031270110: stopper for 3.5mm va-lcp prox tibia plate aiming arm: h679031270100:General Remarks Open-wedge corrective tibia osteotomies are increasingly being used for joint-preserving surgery of the knee joint. The TomoFix knee osteotomy system is based on the Locking Compression Plate system (LCP) and enables angular-stable connections between the screw and plate. This angular stability allows the stable fixation of an open …Inventory Control Form 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 2.7 mm / 3.5 mm Variable Angle LCP Medial Distal Tibia Plates 02.118.002 4 holes, right 02.118.003 4 holes, left 02.118.004 6 holes, right 02.118.005 6 holes, leftThe new Variable Angle LCP Ankle Trauma 2.7/3.5 system was developed to overcome these shortcomings. The low-profile plates feature variable angle locking screw technology and offer more options for screw placement to address a wider range of fracture patterns and to accommodate varied patient anatomies. In addition, these anatomically accurate ...The sequential introduction of plating and screw technologies has led to a total number of more than 20 DePuy Synthes sets to support small fragment procedures involving shoulder, clavicle, elbow, tibia and fibula anatomies. Surgical treatment of small bone trauma occurs worldwide about every 18 seconds and represents about 25% of all bone ...02.108.300, 02.108.300S, 02.108.301... View More. PRODUCT CODES. DESCRIPTION. The Pediatric LCP ™ Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics. The plates feature a universal design to fit both the left and right femurs. Product Specifications.Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN-ADVANCEDTM System (TFNA), Long Nails, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°About This Product. Synthes Calcaneal Plate family including VA Locking Calcaneal Plates 2.7 and Variable Angle Locking Anterolateral Calcaneal Plate 2.7 is intended for temporary fixation, correction, or stabilization of the Calcaneus. Get in Touch with a Sales Consultant.synthes.vo.llnwd.net11 DePuy Synthes Pediatric LCP® Plate System Surgical Technique 4 3 2 1 Preoperative planning is vital for proximal femoral osteotomies. Although there are different ways of planning, they are all designed to achieve the same result. Functional aspect The functional planning is based on a clear AP pelvis x-ray.They reported a high rate, greater than 20%, of early mechanical failure using a Synthes VA-LCP 4.5 mm condylar plate, significantly higher rates than other plate synthesis types. They ... Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model. J Orthop Trauma, 23 (2009), pp. 507-513, 10. ...4 DePuy ®Synthes 4.5 mm VA LCP Curved Condylar Plate System Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which ...Mar 18, 2021 · The NCB-PT® as well as the VA-LCP® allows a variation of screw positioning within specified limits. Besides these two products there are numerous other polyaxial plate systems for the proximal tibia available. However, at the current moment there are no prospective studies including different polyaxial locking plates in proximal tibial fractures.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates 02.107.202 2 holes ...LCP Medial Proximal Tibial Plate 3.5 LCP Medial Proximal Tibial Plate 4.5/5.0 LCP Metaphyseal Plate for distal medial tibia LCP Metaphyseal Plates LCP Olecranon Plate LCP Pediatric Condylar Plate 90°, 3.5 and 5.0 LCP Pediatric Plate System LCP Periarticular Proximal Humerus Plate 3.5 LCP Posterior Medial Proximal Tibial Plate 3.5The RFN-ADVANCED™ System is a retrograde femoral nailing system designed to improve fixation for distal femur fractures 1. As part of the Advanced Nailing System, it is designed to address simple to complex trauma cases 2 with increased fixation and stability. 1,3. Product Specifications. How to Use This Product.pull traction at 30° angle over triangle for reduction. Reaming. ream 1.5mm above size of final nail. Nail Insertion. insert nail over guidewire. Interlocking Screws. targeting guide to place distal interlocking screws first. check femoral neck, get perfect circles of proximal interlocking screws and insert.Remove the drill sleeve, pass the measuring hook through the hole in the plate, and read the screw length from the depth gauge. Alternatively, read the calibration directly after drilling from the drill bit at the back of the drill sleeve. Then remove the drill bit and drill sleeve. Remove the 2.0 mm Kirschner wires.2 Synthes LCP DF und PLT LCP DF und PLT. Plattensystem für das Distale Femur und die Proximale Laterale Tibia. Anatomisch vorgeformte Platten mit niedrigem Profil - Reduzieren Weichteilprobleme - Kein Modellieren der Platten erforderlich Hinweis:Übermässiges und wiederholtes Anbiegen kann die Platte schwächen und ist zu vermeiden.. Inventory Control Form 3.5 mm LCP™ Medial DistIntroduction. Please read these instructions for use, th According to the NAHB report for March, builders remained cautiously optimistic in April as limited resale inventory helped to increase demand in the new home market. According to ... Inventory Control Form 2.7 mm Variable Angle Loc The Synthes 3.5 mm VA-LCP Proximal Tibia Plates are intended to treat fractures of the proximal tibia in adults and adolescents in which the growth plates have fused including: simple, comminuted, lateral wedge, depression, medial wedge, bicondylar combination of lateral wedge and depression, periprosthetic, and fractures with …Evan Goldberg of Oracle NetSuite discusses the new challenges of Just in Time inventory. About this time every year I look forward to heading to Oracle NetSuite’s annual user confe... The Arthrex Proximal Tibia Plating System bui...

Continue Reading